PrimeTest 100 Operating Instructions
16
Plug the supplied 0.5m red IEC lead into the IEC
socket and into a mains outlet on the
extension lead. Plug the mains plug of the
extension lead into the front panel mains socket
on the PrimeTest 100.
The extension lead can now be tested in the
same manner as an IEC as described above.
Note: The protective earth resistance will depend
upon the length of the extension lead and the
size (cross sectional area) of the cable. The
measured value maybe be acceptable even if a
cross is shown next to the R
PE
enunciator.
Table 1: Approximate resistance of protective
earth conductors.
Cord size / current rating
length
0.5mm
2
/(3A) 1.0 mm
2
/(10A) 1.25 mm
2
/(13A)
5m
0.20 0.10 0.10
10m
0.40 0.20 0.20
25m
1.00 0.50 0.40
For further information on protective conductor
resistance and testing of portable appliances can be
found in the Code of Practise for In-service
Inspection and Testing of Electrical Equipment
published by the IEE.